MATERIAL SAFETY DATA SHEET

Section I: General Information

L&L COATINGS CORPORATION

5102 SANTA FE ROAD

TAMPA, FLORIDA 33619

(813) 248-3704 or (813) 248-6723

DATE: JUNE 1996

MSDS CODE

SUPPLIER (IF OTHER THAN MANUFACTURER)

CHEMICAL DESCRIPTION: Biodegradable Cleaner (Concentrate)

PRODUCT USE: 1:2 dilution with H2O produces L&L Power Prep + (Ready-to-Use) May be used by setting pressure washier chemical injector to 1:2 ratio. Then apply as a surface preparation cleaner for the removal of environmental pollutants; paint chalk, grease, mildew and algae stain, dirt and oil, prior to painting. Cleans roofs, walls, floors, most construction and roofing materials; including galvanize, masonry, wood, fiberglass, transite, vinyl, Formica, chrome and stainless.

PRODUCT NAME(S) AS USED ON LABEL: L&L POWER PREP + (CONCENTRATE)

 

SECTION II: HAZARDOUS COMPONENTS

HAZARDOUS COMPONENT

CAS NUMBER

%

Threshold Limit

2-Butoxy ethanol

Sodium Metasilicate

Sodium Hydroxide

Isopropyl Alcohol

111-76-2

6834-92-0

1310-73-2

67-63-0

<10

<1

<1

<2

TLV/PEL: 25-PPM Skin

TLV/PEL: 2mg/m3

TLV/PEL: 2mg/m3

TLV/PEL: 400 PPM; STEL; 400 PPM

SECTION III: PHYSICAL DATA

BOILING POINT (F):

212° F

FREEZE POINT (F)

Not applicable

PH

13.10

VAPOR PRESSURE (mmHg.)

Same as water

% VOLATILE (by VOL.)

90%

SPECIFIC GRAVITY

1.08

VAPOR DENSITY

(Air=1) Same as water

EVAPORATION RATE

(BuAc=1) Same as water

SOLUBILITY IN WATER

Complete

ODOR THRESHOLD (ppm)

Not applicable

PHYSICAL STATE

Liquid

OIL/WATER COEFFICIENT

Not applicable

APPEARANCE AND ODOR: Thin Clear Blue Liquid. Sassafras odor

 

SECTION IV: FIRE & EXPLOSION DATA

FLASH POINT (METHOD): >200° F (T.C.C.)

HMIS RATING:

Health: 1

Flamability: 0

Reactivity: 0

SENSITIVE TO MECHANICAL IMPACT? NA

TO STATIC DISCHARGE? NA

FLAMMABILITY CLASSIFICATION

Product is not flammable

CONDITIONS OF FLAMMABILITY

Product is not flammable

EXTINGUISHING MEDIA

NA

SPECIAL FIREFIGHTING PROCEDURES

Do not enter confined fire space without protective equipment including a NIOSH approved self-contained breathing apparatus. Cool uninvolved containers with water.

UNUSUAL FIRE AND EXPLOSION HAZARDS

None known

HAZARDOUS COMBUSTION PRODUCTS

Normal products of combustion

 

SECTION V: REACTIVITY DATA

STABLE?

YES XX

CONDITIONS OF REACTIVITY: None known

CONDITIONS OF CHEMICAL INSTABILITY: None known

INCOMPATABILITY (MATERIALS TO AVOID): Acids (e.g. muriatic), oxidizers (e.g. bleach) and sodium nitrite

HAZARDOUS DECOMPOSITION PRODUCTS: Normal products of combustion

POLYMERIZATION?

NO XX

CONDITIONS UNDER WHICH PRODUCT WILL POLYMERIZE: Will not occur

 

SECTION VI: TOXICOLOGICAL/HEALTH HAZARD DATA

ROUTES OF ENTRY

SKIN CONTACT? YES

EYE CONTACT? YES

INHALATION? NO

INGESTION? UNLIKELY

EXPOSURE LIMITS

2-Butoxy ethanol

Sodium Hydroxide

Isopropyl Alcohol

ACHGIH

none available

OSHA

TLV/PEL: 25-PPM Skin

TLV/PEL: 2mg/m3

TLV/PEL: 400 PPM; STEL; 400 PPM

SIGNS AND SYMPTOMS OF EXPOSURE

(Acute & Chronic); Harmful to eyes. Irritating on skin. Harmful if swallowed

MEDICAL CONDITIONS GENERALLY AGGRAVATED BY EXPOSURE:

Pre-existing eye, skin, and respiratory disorders may be aggravated

NAME OF TOXICOLOGICALLY SYNERGISTIC PRODUCTS: None known

CARCINOGENICITY DATA:

NTP: No

IARC Monographs: No

OSHA Regulated: No

 

SECTION VII: PREVENTATIVE MEASURES

GLOVES (SPECIFY): Where skin contact may occur, wear rubber or other impervious gloves

EYES (SPECIFY): Where eye contact may occur, wear chemical splash goggles

FOOTWEAR (SPECIFY): Where prolonged or repeated contact is possible, wear rubber or other impervious boots.

CLOTHING (SPECIFY): Wash contaminated clothing before re-use

RESPIRATOR (SPECIFY): None required if good ventilation is maintained. When needed, a NIOSH approved respirator for organic vapors should be worn.

EMERGENCY or ENTRY INTO UNKNOWN CONCENTRATIONS: Self-contained breathing apparatus with full face piece and operated in pressure demand mode or air supplied respirator with full face piece operated in a pressure demand or other positive pressure mode in combination with auxiliary self-contained breathing apparatus operated in pressure demand or positive pressure mode.

ESCAPE: Any air purifying full face piece respirator with highly efficient particulate filter or any appropriate escape type self-contained breathing apparatus.

SPECIFIC ENGINEERING CONTROLS TO BE USED WITH THIS PRODUCT (SPECIFY)

Local and general ventilation in accordance with goo engineering practices should be provided to maintain airborne concentrations of vapor and spray below permissible exposure levels (PELs) specified in Section VI.

PROCEEDURES TO FOLLOW IN CASE OF LEAK OR SPILL

Before attempting clean up, refer to Hazard Data above. Contain spill. Use mop, absorbent, or wet vacuum to collect material for proper disposal. Rinse area with water.

WASTE DISPOSAL PROCEDURES: Treatment, storage, transportation, and disposal of this material must be in accordance with federal, state and local regulations.

HANDLING PROCEDURES AND EQUIPMENT

Use good personal hygiene practice. Wash contaminated clothing and equipment before re-use. Destroy contaminated boots.

STORAGE REQUIREMENTS

Suitable for any general chemical storage area. Store above 40ºF to keep from freezing. Keep container closed when not in use.

D.O.T. SHIP NAME : Hazard Class

Hazard ID #. Packing Group: Non-hazardous

D.O.T. CLASS:

 

SECTION VIII: FIRST AID PROCEDURES

INHALATION: Remove to fresh air. Call a physician if symptoms persist

EYE CONTACT: Flush with water for at least 15 minutes. Rinse with 5% Boric Acid. Call a physician.

SKIN CONTACT: Wash with plenty of water, while removing contaminated clothing and shoes. Wash clothing before re-use. Destroy contaminated footwear.

INGESTION: Drink large quantities of water. Do not induce vomiting. Seek immediate medical attention. Never give anythin by mouth to an unconscious person.

 

SECTION IX: PREPARATION INFORMATION

PREPARED BY: T. O. Linville

PHONE: (813)248-6723

DATE PREPARED: June 1996

The information on this data sheet represents our current data and best opinions as to the proper use of this product under normal conditions. Any use of the product which is not in conformance with this data sheet or which involves using the product in combination with any other product or any other process is the responsibility of the user.